Both chemistries run on hydrogen, but they suit different jobs in an aircraft. This page sizes each one from the twin for the three steps of the hydrogen-electric ladder, and sets the results against public roadmap figures. Every model number is a development result, not validated.
PEM model
SOFC model
Fuel-cell explorer
See the system to scale
Cells solid and to scale, balance of plant in grey X-ray. Drag to turn, pinch or scroll to zoom.
Loading the 3D view
PEM plates
SOFC tubes
Balance of plant (placeholder)
How these figures are worked out, and their sources
PEM stacks. Planar cells, 370 per stack at 1.34 mm, the Toyota Mirai cell thickness 7; 280 cm² active area assumed, on a plate 2.5 times larger (the Mirai's ratio) 8.
SOFC cells. Reference cell (default) 0.6 W/cm² at 0.8 V, inside the published 0.5–1 W/cm² range; high-performance lab cell 1.0 W/cm² 16. Both are linear cells (open circuit 1.10 V assumed) drawn as 2 mm micro-tubes, 50 mm active, 1 mm gap. The lab rig cell is the twin's own 7 mm tube (9.07 cm²). All in bundles of 20 × 20 tubes.
Balance-of-plant power. PEM from the twin's compressor model (2.51 bar, stoichiometry 2, 68 % efficient, plus 0.3 kW per stack). SOFC blower assumed (stoichiometry 4, pressure ratio 1.1). Ground-level air; altitude raises compressor power.
Mass, today's hardware (default). PEM stack 2.04 kW/kg (114/56 rated reference) 12; PEM system 1.4 kW/kg, a manufacturer claim with an unreconciled equipment boundary 14 (DOE 2015 system: 0.659 11); SOFC stack 0.3 kW/kg, mid-range of 0.1–0.5 for planar stacks 15. No SOFC system mass is published, so none is shown.
Development targets (switch). PEM: FlyZero stack 7 (2026) to 16 (2050) kW/kg and its stack + BoP range 1. SOFC: about 3 kW/kg, the HYLENA target 15. Targets are not demonstrated hardware.
Boundaries. Cell W/cm², stack kW/kg and system kW/kg are different things and are never converted into one another. Baseline BoP mass is unknown because Mirai stack and ZeroAvia system references have different equipment boundaries. Only target-case BoP mass is system minus stack.
Checked against the Toyota Mirai stack789: cell count at its rated point (378 against 370), compressor power (16.3 against up to 15 kW) and stack volume agree. The PEM model's membrane resistance is refitted to one published Mirai point: a calibration, not a validation. Details in docs/MIRAI_BENCHMARK.md and docs/POWER_DENSITY_BOUNDARIES.md.
Live SOFC calculation
Move the voltage, see the cell
Benefits and assumptions
PEM · proton-exchange membrane
Benefits
Starts in under a minute and follows load, including transients 2
More power per area: Mirai-class cells give 0.78 W/cm² at 1 A/cm², against 0.60 W/cm² for the reference SOFC cell at 0.8 V 187
Far more power per kilogram today: stacks about 2.0 kW/kg (Mirai Gen1) against 0.1–0.5 kW/kg for planar SOFC stacks 1215
Published flight roadmap: FlyZero 2.0–2.5 kW/kg stack + BoP by 2030 1
Flown in commuter demonstrators; FlyZero TRL 6 by 2026 13
Assumptions in this twin
Mirai-class calibration: membrane resistance refitted to one public Toyota Mirai point (0.67 V at 1.9 A/cm²); other coefficients from the lab anchor
80 °C, 2.53 bar, RH 0.6, cathode stoichiometry 2; sized at 1.0 A/cm² (0.784 V, 63 % LHV)
Mass, today’s hardware (default): stack 2.04 kW/kg (114/56, Mirai Gen1 rated reference); system 1.4 kW/kg (ZeroAvia claim, equipment boundary not reconciled; DOE 2015 integrated system 0.659). FlyZero targets appear only under “Development targets”
The frozen lab anchor still loses to a fixed 0.7 V baseline on measured lab data (120.6 vs 34.2 mV error)
SOFC · solid oxide
Benefits
Higher efficiency: 64 % against 63 % (LHV), so 2 % less hydrogen for the same power 18
Less heat to reject, and at 600–1,000 °C it is high-grade: usable by a turbine or heat exchanger 183
Fuel flexible and tolerant of CO and other contaminants 23
Steady duty suits APU, ground power and turbine-hybrid roles 23
Assumptions in this twin
Reference cell (default): 0.6 W/cm² at 0.8 V, a screening assumption inside the published 0.5–1 W/cm² range; linear cell, open circuit 1.10 V assumed, drawn as 2 mm micro-tubes
High-performance lab cell (switch): 1.0 W/cm² at 0.8 V, matching advanced laboratory cells (a metal-foam cell peaked at 1.01 W/cm², 650 °C); not demonstrated stack performance
Lab rig cell (switch): the twin’s frozen 7 mm tubular cell at 800 °C, 50 mL/min fuel, 0.24 W/cm² at 0.8 V; fuel-limited below about 0.6 V
Sized at 0.8 V (0.75 A/cm² in the selected default)
Stack mass 0.3 kW/kg today (planar stacks 0.1–0.5); HYLENA’s about 3 kW/kg is a target, shown only under “Development targets”. No published SOFC system mass, so none is invented
Cell W/cm² is never converted to kW/kg: stack mass depends on interconnects, seals, insulation and packaging
Start-up (tens of minutes to hours), thermal cycling and altitude not modelled; acceptance gate blocked
The use case
Scaling up step by step
Step 1 · by 2030Business + taxi, 4–9 seats350–600 kW
Ladder as presented by H2FLY 5. Sizing below uses the top of each power band.
From the twin
What one cell delivers
PEM leads per square centimetre and, by a wide margin, per kilogram. The Mirai-class PEM cell peaks at 1.41 W/cm²; the reference SOFC cell gives 0.60 W/cm² at 0.8 V, and advanced laboratory SOFC cells reach about 1 W/cm² (the high-performance option). The twin's own rig SOFC cell reaches 0.35 W/cm²: a 7 mm research tube on a small fuel supply, not a stack cell.
Boundary
SOFC
PEM
Sources
Cell power per active area W/cm²
About 0.5–1; advanced lab cells about 1 (1.01 peak, metal-foam cell, 650 °C)
Screening benchmarks, not guaranteed continuous ratings. W/cm² is never converted to kW/kg, and cell figures are never relabelled as stack or system figures. Data: datasets/public/sofc-pem-power-density-background.json.
Toyota specifications; the masses are not independently weighed. Argonne measured Gen1 peak stack output in vehicle tests, rising to 114.6 kW over back-to-back accelerations and about 110–114 kW depending on temperature 9: this supports the peak rating, not a continuous one. The explorer and the /api/v1/system response count whole stacks at fixed mass: at 600 kW gross, 6 Gen1 stacks (336 kg) or 5 Gen2 stacks (260 kg), excluding supporting equipment. FlyZero targets stay separate (“Development targets”). The frozen models are unchanged, and these benchmarks are not twin validation.
Gallery: fuel cells from car to aircraft
MiraiThe fuel-cell system around the stack: air, hydrogen and coolant loops. Everything except the stack is balance of plant.
MiraiIsometric layout of the second-generation car: stack under the hood, three tanks in a “T”, battery above and motor on the rear axle, body drawn from published dimensions.
AircraftAirbus ZEROe fuel-cell concept, about 100 seats: four 2 MW pods, each with its own fuel cells and heat exchanger (distributed cooling); two liquid-hydrogen tanks behind the cabin.
AircraftGKN Aerospace H2GEAR: all hydrogen and fuel cells in one rear zone; liquid hydrogen cools a central helium loop that cools the DC feeders, inverters and wing-mounted cryogenic motors (Hales et al. 2023).
Vector schematics redrawn by Vassal in DesignCraft from public Toyota, Airbus and GKN Aerospace material (GKN: Hales et al., AIAA AVIATION 2023). Indicative, not to scale; assumptions are marked on each drawing. Every drawing comes in light and dark versions.
PEM Mirai-class 80 °CPEM lab cell 75 °C (frozen anchor)SOFC high-performance lab cell (scenario)SOFC reference cell (screening)SOFC rig cell 800 °C Twin model outputs, not validated. PEM Mirai-class: membrane resistance refitted to a public Toyota Mirai point, 2.53 bar; lab cell: frozen anchor, 2.51 bar; both RH 0.6, stoichiometry 2. SOFC reference and high-performance cells: linear screening cells (0.6 and 1.0 W/cm² at 0.8 V). SOFC rig: frozen v1 tubular cell, 3 % steam, 50 mL/min. The rig curve bends down near 0.6 A/cm² because the rig fuel flow runs out (90 % utilisation at 0.5 V); a stack fed more fuel would go further.
Sized for each step
Same power, different machines
Each stack is sized for the net electrical power of the step: PEM at 1.0 A/cm², SOFC at 0.8 V. Which cells you assume changes the answer; at 2,000 kW:
PEM model
SOFC model
Hydrogen, kg/h (PEM / SOFC)
SOFC area vs PEM
Mirai-class stack
Reference cell
96 / 94
1.3×
Mirai-class stack
High-performance lab cell
96 / 94
0.8×
Mirai-class stack
Lab rig cell
96 / 94
3.2×
Lab cell
Reference cell
115 / 94
1.1×
Lab cell
High-performance lab cell
115 / 94
0.7×
Lab cell
Lab rig cell
115 / 94
2.7×
Step 1 · by 2030Business + taxi, 4–9 seats · sized at 600 kW
Step 3 · from 2040Larger single-aisle · sized at 4,000 kW
PEM
SOFC
PEM
SOFC
PEM
SOFC
Operating point
0.656 V · 1.00 A/cm²
0.800 V · 0.30 A/cm²
0.656 V · 1.00 A/cm²
0.800 V · 0.30 A/cm²
0.656 V · 1.00 A/cm²
0.800 V · 0.30 A/cm²
Active area
91.4 m²
247 m²
305 m²
825 m²
610 m²
1,649 m²
Hydrogen at full power
34.4 kg/h
28.2 kg/h
115 kg/h
94 kg/h
229 kg/h
188 kg/h
Heat to reject
546 kW at ~75 °C
340 kW at ~800 °C
1,820 kW at ~75 °C
1,133 kW at ~800 °C
3,639 kW at ~75 °C
2,266 kW at ~800 °C
Whole Mirai stacks (Gen1 / Gen2)
6 stacks, 336 kg / 5 stacks, 260 kg
—
18 stacks, 1008 kg / 16 stacks, 832 kg
—
36 stacks, 2016 kg / 32 stacks, 1664 kg
—
Stack mass today (stack only)
295 kg scaled at 114/56 kW/kg
1,200–6,000 kg at 0.1–0.5 kW/kg
982 kg scaled at 114/56 kW/kg
4,000–20,000 kg at 0.1–0.5 kW/kg
1,965 kg scaled at 114/56 kW/kg
8,000–40,000 kg at 0.1–0.5 kW/kg
System mass today (stack + BoP)
429 kg at 1.4 kW/kg (claim)
Not published
1,429 kg at 1.4 kW/kg (claim)
Not published
2,857 kg at 1.4 kW/kg (claim)
Not published
Development targets (scenario)
240 – 300 kg system (FlyZero 2030)
200 kg stack (HYLENA 3 kW/kg)
667 – 800 kg system (FlyZero 2035)
667 kg stack (HYLENA 3 kW/kg)
1,143 – 1,333 kg system (FlyZero 2050)
1,333 kg stack (HYLENA 3 kW/kg)
Screening estimate from archee.api.size_stack: stack only, 100 % hydrogen utilisation, LHV heat basis, no compressor, converter or balance-of-plant losses. Mass rows use today’s published hardware 121415; the last row is development targets 115, not demonstrated. No published SOFC system mass.
Try it
Size your own case
Computed in your browser with the same code as the web API (/api/v1/size); SOFC current density is interpolated from the twin's 800 °C curve.
Beyond the curves
How they differ in an aircraft
PEM
SOFC
Source
Operating temperature
65–95 °C today; FlyZero target 80 °C (2026) → 100 °C (2035)
Low-grade, near 80 °C, with stack efficiency typically 40–50 %: large radiators or vapour-compression cooling; HT-PEM (PBI, 30–90 °C hotter) eases this
High-grade, hundreds of °C: usable by a turbine or heat exchanger, but complex thermal management
Ground markets can retire some risks before flight. They cannot prove power per kilogram, altitude, vibration or certification, which must be funded as flight-specific work.
Risk
PEM ground route
SOFC ground route
Carries over to flight
Stack durability under real hours
Backup and ground power, buses
Data-centre and distributed power (steady duty suits SOFC)
Partial: flight duty cycle differs
Manufacturing cost, yield and UK supply chain
Volume from ground markets
Volume from data-centre orders
High
Controls, health monitoring and AI
Fleet data to train and validate models
Fleet data to train and validate models
High
Thermal management
Low-grade heat rejection at scale
High-grade heat recovery and integration
Partial: ram air and altitude differ
kW/kg, altitude, vibration, certification
Not proved on the ground
Not proved on the ground
None: fund separately
Same aircraft, third energy store
Where the battery fits
Neither cell is flown alone. A fuel-cell regional aircraft also carries a battery buffer for start-up and transients, which the battery twin can size.
Both models are frozen development candidates. The PEM model loses to a fixed 0.7 V baseline on measured data; the SOFC acceptance gate is blocked. See the evidence board.
No mass model: specific power comes from published targets and claims, not from the twin.
SOFC thermal cycling, start-up energy and altitude effects are not modelled.
Published figures are quoted from public sources only.